Telecommunication Testing

Telecommunication Testing

Wireless devices have discovered its more extensive applications across variety of very high-tech products (Keyboard, Scanners, Laptops, and Printers etc.) to very low-end products including electronic toys. Numerous products operated on electrical power, can be functioned through the wireless devices namely Wi-Fi routers/modems, wireless mouse, wireless keyboard, wireless headphones, wireless smart watches, Wi-Fi USB pen-drives, wireless speakers etc. primarily for Convenience and Safety of people. Hence, Safety is also a matter of concern since it radiates certain amount of power.

 

Telecommunications Engineering Centre (TEC), a DoT nodal agency has been tasked to undertake Mandatory Testing & Certification of Telecom Equipment (MTCTE) for the sector to preview nearly 50 products in order to ensure network and device safety.

To address this issue, Hi Physix will add the testing facilities to examine wireless devices operations, performance and safety. The EMC/EMI test facility would also cover tests on various low power wireless devices are being widely used in the IT & Electronic products for satisfactory remote operations as per IS/IEC/TEC requirements.

At present Hi Physix is designated as a CAB by TEC vide TECCertificate No. : TEC/MRA/CAB/IND-D/58.The related scope of testing and testing charges are as below:

TEC Certificate No. : TEC/MRA/CAB/IND-D/58

Testing Charges for Mandatory Testing and Certification of
Telecom Equipments (MTCTE)

Sl. No Telecom Equipment/Product Technical Regulation Type of Testing Testing Charges (for each requirement)
Class 1 & Class 2 Class 3
1 Information Technology Equipment
– Safety Requirements
IEC 60950- 1:2005 +A1:2009+A2:
2013/ IS 13252:2010+A 1+A2
Verification of Component (Cl. 1.5 except
1.5.3, 1.5.6, 1.5.9.1)
3000 3000
Power Interface (Cl. 1.6) 5000 3000
Verifications of Marking and
Instructions
(Cl. 1.7)
3000 3000
Protection from Electric Shock and
Energy Hazards
(Cl. 2.1)
5000 3000
SELV Circuits (Cl. 2.2) 5000 3000
Limited Power Sources (Cl. 2.5) 5000 3000
Provisions for Earthing and Bonding (Cl.
2.6)
5000 0
Overcurrent and Earth Fault Protection
in Primary Circuits (Cl. 2.7)
3000 0
Safety Interlocks (Cl. 2.8 except 2.8.5,
2.8.7)
5000 3000
Electrical Insulation (Cl. 2.9) 25000 10000
Clearances, Creepage Distances and
Distances through Insulation (Cl. 2.10)
5000 3000
Wiring, Connections and Supply-
General Requirements (Cl. 3.1)
2000 2000
Connection to a Mains Supply (Cl. 3.2) 3000 0
Wiring Terminals for External
Conductors (Cl. 3.3)
3000 3000
Disconnections for the Mains Supply
(Cl. 3.4)
3000 0
Interconnection of Equipment (Cl. 3.5) 3000 3000
Stability (Cl. 4.1) 3000 3000
Mechanical Strength (Cl. 4.2 except
4.2.8)
5000 3000
Verification of Design and Construction
(Cl. 4.3 except 4.3.13.2, 4.3.13.3,
4.3.13.4, 4.3.13.5)
7000 5000
Protection against Hazardous Moving
Parts (Cl. 4.4)
3000 2000
Thermal Requirements (Cl. 4.5) 5000 3000
Opening in Enclosures (Cl. 4.6) 3000 2000
Resistance to Fire (Cl. 4.7) 5000 3000
Electrical Requirements and Simulated
Abnormal Conditions- Touch Current
and Protective Conductor Current (Cl.
5.1)
3000 2000
Electric Strength Test (Cl. 5.2) 3000 2000
Abnormal Operation and Fault
Conditions (Cl.5.3)
5000 3000
Connection to the Telecommunication
Network (Cl.6)
5000 5000
Connection to Cable Distribution
System (Cl. 7)
5000 5000
Total Charges: 135000 80000
Sl. No Telecom Equipment/Product Technical Regulation Type of Testing Testing Charges (for each requirement)
Battery Cells
2 Secondary Cells and Batteries containing
Alkaline or other non-acid Electrolytes
(Lithium System) – Safety Requirements
IS 16046 (Part 2):2018/ IEC 62133-2:2017 External Short Circuit (Cell) (Cl. 7.3.1) 0 10000
External Short Circuit (Battery) (Cl. 7.3.2) 10000 0
Free Fall (Cl. 7.3.3) 10000 10000
Thermal Abuse (Cl. 7.3.4) 0 10000
Crush (Cells) (Cl. 7.3.5) 0 15000
Overcharging of Battery (Cl. 7.3.6) 15000 0
Forced Discharge (Cl. 7.3.7) 0 10000
Total Charges: 35000 55000
Sl. No Telecom Equipment/Product Technical Regulation Type of Testing Testing Charges (for each requirement)
Upto
250AH
>250
AH to 500AH
>500
AH to 5000AH
>500
0AH to 8000AH
3 Tubular Valve Regulated Lead Acid
(VRLA) Batteries based on
gel technology
TEC /GR/TX/ BAT- 003/02 MAR201 1 Test for Capacity (Cl. 1.3.1) 40000 50000 60000 80000
Charging (Cl. 1.3.2) 15000 15000 15000 15000
Float Voltage (for Battery) (Cl. 1.3.3) 30000 30000 30000 30000
Voltage During Discharge (Cl. 1.3.4) 5000 5000 5000 5000
Loss of Capacity During Storage (Cl. 1.3.7) 200000 225000 250000 300000
Ampere-Hour Efficiency (Cl. 1.3.8) 10000 10000 10000 10000
Watt-Hour Efficiency (Cl. 1.3.9) 10000 10000 10000 10000
Short Circuit Test Apparatus (Cl. 1.3.10) 50000 50000 50000 50000
Cell Matching (A) Voltage & Capacity Matching (B) Conductance Matching (Cl. 1.3.11) 20000 20000 20000 20000
Service Life or Ageing Test (Cl. 1.3.12) 400000 550000 700000 800000
Partial Test of Charge Test (Cl. 1.3.13) 300000 450000 600000 700000
Thermal Runway (Cl. 1.4.8) 30000 30000 30000 30000
Fire Retardant (Cl. 1.4.9) 20000 20000 20000 20000
Total Charges: 1140000 1475000 1810000 2080000
Sl. No Telecom Equipment/Product Technical Regulation Type of Testing Testing Charges (for each requirement)
Upto
250AH
>250
AH to 500AH
>500
AH to 5000AH
>5000
0AH to 8000AH
4 Valve Regulated Lead Acid Batteries TEC /GR/TX/ BAT-001/04 JUN 2011 Thermal Runway Test (Cl. 1.4.8) 30000 30000 30000 30000
Fire Retardant (Cl. 1.4.9) 20000 20000 20000 20000
Test for Capacity (Cl. 5.1) 40000 50000 60000 80000
Charging (Cl. 5.2) 15000 15000 15000 15000
Float Voltage (for Battery) (Cl. 5.3) 30000 30000 30000 30000
Voltage During Discharge (Cl. 5.4) 5000 5000 5000 5000
Transient Response (Cl. 5.6) 10000 10000 10000 10000
Loss of Capacity During Storage (Cl. 5.7) 200000 225000 250000 300000
Ampere-Hour Efficiency (Cl. 5.8) 10000 10000 10000 10000
Watt-Hour Efficiency (Cl. 5.9) 10000 10000 10000 10000
Short Circuit Test (Cl. 5.10) 50000 50000 50000 50000
Cell Matching (A) Voltage & Capacity Matching (B) Conductance Matching
(Cl. 5.11)
20000 20000 20000 20000
Service Life or Ageing Test (Cl. 5.12) 300000 450000 600000 700000
Total Charges: 740000 925000 1110000 1280000